If the malfunction still exists 4 minutes after the device stops due to compressor protection, the error code will be directly displayed on the display of the indoor unit. In other cases, an error code may be displayed by pressing the LIGHT button 6 times in 4 seconds.
|
Codes |
Indication |
Malfunction |
Possible reasons |
|
E2 |
RUN indicator off for 3s and blinks 2 times |
Inner spiral defrost protection |
|
|
E4 |
RUN indicator off for 3s and blinks 4 times |
Compressor overheat protection |
|
|
E5 |
RUN indicator off for 3s and blinks 5 times |
Overvoltage Protection |
|
|
E6 |
RUN indicator off for 3s and blinks 6 times |
Communication failure |
|
|
HER |
HEAT indicator off for 3s and blinks 15 times |
EEPROM error (memory chip) |
Replace indoor unit board |
|
F0 |
COOL indicator off for 3s and blinks 10 times |
Lack of Freon or Block Protection |
|
|
F1 |
COOL indicator off for 3s and blinks 1 time |
Malfunction INTERNAL AIR TEMPERATURE SENSOR |
|
|
F2 |
COOL indicator off for 3s and blinks 2 times |
Malfunction of the INTERNAL TEMPERATURE SPIRAL sensor (RT2) |
|
F3 |
COOL indicator off for 3s and blinks 3 times |
Outside sensor sensor malfunction temperature |
|
|
F4 |
COOL indicator off for 3s and blinks 4 times |
Malfunction of the outdoor temperature sensor |
|
|
F5 |
COOL indicator off for 3s and blinks 5 times |
Compressor temperature sensor malfunction |
|
|
H3 |
HEAT indicator off for 3s and blinks 3 times |
Compressor overload protection |
|
|
H4 |
HEAT indicator off for 3s and blinks 4 times |
System overload |
The system is unstable, check that the evaporator and condenser are dirty and blocked. |
|
H6 |
HEAT indicator off for 3s and blinks 6 times |
no feedback from indoor unit motor |
|
|
H7 |
HEAT indicator off for 3s and blinks 7 times |
Sync failure |
|
|
|
HEAT indicator off for 3s and blinks 11 times |
Air conditioner start failure |
|
|
P7 |
HEAT indicator off for 3s and blinks 18 times |
Radiator temperature sensor malfunction |
|
|
P8 |
HEAT indicator off for 3s and blinks 19 times |
Radiator temperature sensor overheat protection |
|
|
PH |
COOL indicator off for 3s and blinks 11 times |
High voltage |
|
|
PL |
HEAT indicator off for 3s and blinks 21 times |
Low voltage |
|
|
U1 |
HEAT indicator off for 3s and blinks 13 times |
Compressor phase failure |
Replace outdoor main board Replace the outdoor unit board |
|
U5 |
COOL indicator off for 3s and blinks 13 times |
AC problem detected |
Replace the outdoor unit board |
|
U7 |
COOL indicator off for 3s and blinks 20 times |
Check Valve Malfunction |
|
|
UA |
The HEAD and COOL indicators flash 12 times simultaneously |
Configuration errors |
The indoor unit does not match the outdoor unit |
|
UF |
The HEAD and COOL indicators blink 7 times simultaneously |
Zero transition protection (indoor unit) |
Replace indoor unit board |
|
UH |
The HEAD and COOL indicators blink 8 times simultaneously |
There is no feedback from the motor of the external unit |
Can this malfunction occur when an indoor unit motor is used? |
|
UU |
HEAD and COOL indicators blink 11 times simultaneously |
DC over current High voltage |
|
Airwell HHF 024-N11 / YGF 024-H11