See also: Ballu Air Conditioners Service Manuals PDF
Ballu KF -1802GWE, KF -2302GWE Error Codes
|
Error code |
Error description |
Display |
|||
|
High Power |
Operation |
Timer |
Power |
||
|
1 |
Shorted or broken air temperature sensor |
|
|
|
* |
|
2 |
Evaporator temperature sensor shorted or broken |
|
|
* |
|
|
3 |
Evaporator Freezing |
|
|
* |
* |
|
6 |
Power problems |
|
* |
* |
|
|
7 |
Compressor overload |
|
* |
* |
* |
|
8 |
The fan motor does not spin |
* |
|
|
|
|
13 |
Error on the memory chip on the board |
* |
* |
|
* |
Ballu KFR- 2688GW/BPE Error Codes
|
Error description |
Display |
|||
|
Timer lamp |
Running lamp (blue) |
Running lamp(red) |
Power lamp |
|
|
Air temperature sensor problem |
|
|
|
* |
|
Evaporator temperature sensor shorted or broken |
|
|
* |
|
|
Evaporator Freezing |
|
|
* |
* |
|
Evaporator Overheat |
|
* |
|
|
|
No connection between indoor and outdoor units |
|
* |
|
* |
|
Eating problems |
|
* |
* |
|
|
Compressor overload |
|
* |
* |
* |
|
Fan motor failure |
* |
|
|
|
|
Malfunction of the temperature sensor of the external unit |
|
|
|
★ |
|
Condenser Sensor Malfunction |
|
|
★ |
|
|
Overloading the entire system |
|
★ |
★ |
|
|
No load compressor open |
|
★ |
★ |
★ |
|
Supply voltage problem |
★ |
|
|
|
|
External unit overload during cooling |
★ |
|
★ |
|
|
Defrost mode |
★ |
|
★ |
★ |
|
Inverter module malfunction |
★ |
★ |
|
|
|
Faulty memory chip on the board of the external unit |
★ |
★ |
|
★ |
★ - the indicator is constantly on
* - the indicator blinks
Ballu inverter conditioners Error Codes
KFR - 5701GW/Y2BPE
KFR - 2601GW/BPE*2
KFR - 28GW /BPE*2, 2801
* - the indicator blinks
|
Error code |
Display |
Description of the problem |
Cause of malfunction |
|||
|
Run |
Standby |
Timer |
Highefficiency |
|||
|
1 |
★ |
|
|
|
Outdoor ambient temperature sensor abnormal |
Thermistor short-circuited or open circuited |
|
2 |
|
★ |
|
|
Outdoor heat exchanger temperature sensor abnormal |
Thermistor short-circuited or open circuited |
|
3 |
★ |
★ |
|
|
Compressor overheated |
Thermistor short-circuited or open circuited, or compressor overheated |
|
4 |
|
|
★ |
|
Outdoor capillary tube A temperature sensor in trouble |
Thermistor short-circuited or open circuited |
|
5 |
★ |
|
★ |
|
Outdoor capillary tube B temperature sensor in trouble |
Thermistor short-circuited or open circuited |
|
6 |
|
★ |
★ |
|
Overcurrent trouble |
Too large electric current in the outdoor unit |
|
7 |
★ |
★ |
★ |
|
No load |
Compressor not connected or the module damaged |
|
8 |
|
|
★ |
|
Supply voltage abnormal |
|
|
9 |
★ |
|
★ |
|
Too high or too low supply voltage |
|
|
12 |
|
|
★ |
★ |
Malfunction of IPM power module |
|
|
13 |
★ |
|
★ |
★ |
Incorrect EEPROM data |
|
|
14 |
|
★ |
★ |
★ |
Outdoor air circulation temperature sensor in trouble |
|
Ballu Error Codes List
- E1, E2, E3, E4 - the temperature sensor is shorted or broken (indoor or outdoor unit, condenser temperature, evaporator temperature)
- E6 - protection of the external unit has worked
- E8 - clogged electrostatic filter
- P4 - error on the evaporator sensor, too low / high temperature (the compressor switches off automatically)
- P5 - error on the capacitor sensor, too low / high temperature (the compressor switches off automatically)
- P6 - the defrost or delay mode of the temperature of the internal heat exchanger is activated
- EA - the firmware has flown, the EEPROM is faulty (determined empirically, replacing the ROM chip with the firmware removed the error)
Error codes of the BSC series; BV; BR
- E1 - error of the internal temperature sensor
- E2 - error of the evaporator temperature sensor
- E5-system entered protection mode by mistake of the outdoor unit
- E6 - error of the fan motor of the indoor unit