Midea MSE Series 07, 09, 12, 18
|
Malfunction |
Operation lamp |
Timer lamp |
|
The thermal protection of the compressor and other overload protection have already worked 4 times. |
Not glow |
Flashing |
|
for more than a minute the fan of the indoor unit does not work |
Flashing |
Not glow |
|
The indoor or pipe thermistor of the indoor unit is not working |
Flashing |
Steady on |
|
EEROM board error |
Steady on |
Flashing |
|
Phase reversed and neutral |
Flashing |
Flashing |
Models 24 and 28 of the Midea MSE Series
|
Description of malfunction |
Operation lamp |
Timer lamp |
Defrosting lamp |
Auto lamp |
|
The thermal protection of the compressor and other overload protection have already worked 4 times. |
Flashing |
Flashing |
Flashing |
Flashing |
|
Faulty indoor unit temperature sensor |
Does not burn |
Flashing |
Not glow |
Does not burn |
|
Faulty indoor unit temperature sensor |
Flashing |
Does not burn |
Not glow |
Does not burn |
|
The temperature probe of the outdoor unit is not working |
Does not burn |
Not glow |
Flashing |
Does not burn |
|
The protection of the outdoor unit has worked (for 380V) or the outdoor unit thermistor is not working properly. |
Does not burn |
Does not burn |
Flashing |
Flashing |
|
Phase reversed and neutral |
Flashing |
Flashing |
Not glow |
Does not burn |
|
EEROM board error |
Does not burn |
Flashing |
Not glow |
Flashing |
|
Interconnect cable break for 380V models |
Does not burn |
Does not burn |
Not glow |
Flashing |
Midea Error Codes Models MSE inverter
|
Error Code |
Type of error |
Descriptions |
|
E0 |
Error / Failed EEPROM |
replace indoor unit board |
|
E1 |
Incorrect interconnect |
not a guarantee , possibly elements on the boards of indoor and outdoor units are burned out |
|
E2 |
Incorrect Zero Phase Connection |
correctly connect zero and phase |
|
E3 |
Faulty indoor fan motor |
replace motor |
|
E4 |
Reserve |
* |
|
E5 |
Faulty / open / no contact of the outdoor unit thermistor |
check contacts, replace thermistor |
|
E6 |
Faulty / open / no contact indoor unit thermistors |
checking contacts, replacing thermistors |
|
P0 |
Over current / faulty IPM |
cleaning of heat exchangers, wrong amount of refrigerant in the system, module replacement, check compressor windings |
|
Р1 |
Supply voltage too high or too low |
no guarantee |
|
P2 |
High discharge temperature |
not a guarantee , pollution of heat exchangers, lack of refrigerant, air in the system |
|
P3 |
Too low street temperature |
not a guarantee , shutdown at -15С, inclusion at -12С |
|
R4 |
Compressor malfunction |
check the resistance of the compressor windings |
Error codes for Midea split systems Models 07, 09, 12, 18 of the MSG series
|
Description of malfunction |
Operation lamp |
Timer lamp |
Defrosting lamp |
|
Compressor overload protection 4 times |
Flashing |
not glow |
Flashing |
|
For more than a minute, the indoor unit fan does not turn on. |
not glow |
Flashing |
Flashing |
|
No compressor starts |
Flashing |
Flashing |
Flashing |
|
The tube thermistor on the indoor unit is not working |
not glow |
not glow |
Flashing |
|
Faulty indoor thermistor on indoor unit |
not glow |
Flashing |
not glow |
|
Error (failure) EEROM |
Steady on |
Flashing |
not glow |
Error codes of split systems Midea Model 24 of the MSG series
|
Flashing - Operation, Timer, Defrosting, Auto |
4 times compressor overload protection tripped |
|
Flashing - Timer |
The indoor thermistor does not work on the indoor unit |
|
Flashing - Operation |
Pipe thermistor does not work on indoor unit |
|
Flashing - Defrosting |
The thermistor on the outdoor unit does not work |
|
Flashing - Defrosting, Auto |
The protection of the outdoor unit has worked (for 380V) or the outdoor unit thermistor does not work |
|
Flashing - Auto, |
EEROM board error |
Error Codes MSG-30/36HR
|
Indoor Unit Indication |
|
|
LED indication |
|
|
Operation, Timer, Defrosting LEDs blink |
Four times in an hour, the operating current was exceeded. |
|
Timer LED flashes |
Open or short in room thermistor |
|
Operation LED flashes |
Open or short pipe thermistor |
|
Defrosting LED flashes at 5 Hz |
Open or short circuit outdoor thermistor. block |
|
Operation, Timer, |
EEPROM Error |
|
LEDs Defrosting, AUTO, |
Outdoor unit error |
|
AUTO LED flashes |
Block Error |
|
|
|
|
|
|
|
Indication of outdoor unit |
|
|
LED indication (number of flashes at 2-second intervals) |
|
|
5 flashes |
Block Connection Error |
|
4 flashes |
Incorrect phasing (3 phase model) |
|
3 flashes |
High pressure |
|
2 flashes |
Broken or shorted thermistor |
|
1 flash |
Indoor Unit Failure |
|
Steady on |
Normal work |
Error codes Midea MSX 07-18
|
Midea Error Codes MSX Series 07-18 |
|
|
E1 |
EEPROM crash |
|
E2 |
Neutral punches to the ground |
|
E3 |
Error controlling the speed of the electric motor int. Block (Hall sensor not interrogated) |
|
E4 |
Compressor starting current exceeding at start 4 times in a row |
|
E5 |
Error on indoor unit air thermistor |
|
E6 |
Error on the tube temperature sensor of the indoor unit |
Error codes Midea MSX 21-24
|
E1 |
EEPROM crash |
|
E4 |
Compressor current overload four times per hour. |
|
E5 |
Error in temperature probe of indoor unit by air |
|
E6 |
Error on the tube temperature probe of the indoor unit |
|
E7 |
Error on the tube temperature probe of the outdoor unit |
|
E8 |
Zero and phase mixed up |
|
E9 |
Incorrect connection of indoor and outdoor unit (incorrect communication) |
|
Self-diagnosis |
||||
|
Indoor unit |
|
|
|
|
|
No. |
Type |
Descriptions |
Indication |
Note |
|
1 |
Protection |
Compressor overload current tripped four times |
LED blinks operation+timer+defrosting |
The air conditioner does not turn on. The error is reset after a complete disconnection from the mains. |
|
2 |
Protection |
Outdoor unit protection |
All leds blink |
Automatically reset to correct the error, except for the thermistor of the tube outdoor unit |
|
3 |
Error |
Indoor unit thermistor |
Flashing timer |
|
|
4 |
Error |
Thermistor tube indoor unit |
Operation flashes |
|
|
5 |
Error |
Outdoor unit tube thermistor |
Flashing defrosting |
|
|
6 |
Error |
Thermal protection |
Operation + timer flashing |
|
|
Outdoor unit |
|
|
|
|
|
Three-phase models 36, 48, 60 kbtu, outdoor unit of universal type |
|
|||
|
Type |
Content |
LED1 |
LED2 |
LED3 |
|
OK |
Job |
Glows |
Off |
Off |
|
Error |
Incorrect phase rotation |
Blinks |
Off |
Off |
|
Error |
No one or two phases, phase imbalance A and B |
Blinks |
Off |
Off |
|
Error |
No phase C, imbalance in phase C |
Off |
Off |
Off |
|
Error |
Low boiling pressure |
Blinks |
Blinks |
Off |
|
Error |
Over current |
Off |
Off |
Blinks |
|
Error |
Outdoor unit tube thermistor (T3) |
Off |
Blinks |
Blinks |
|
Error |
Outdoor unit thermistor by air (T4) |
Off |
Blinks |
Off |
|
OK |
Expectation |
Blinking (slow) |
Blinking (slow) |
Blinking (slow) |
Error codes of the external MDV block
|
Error code |
Description |
|
E1 |
Error on the phase monitor (phase reversed, the absence of one of the phases) |
|
E2 |
Inter-unit interruption |
|
E3 |
Contact with the T3 temperature sensor does not work |
|
E4 |
Does not work contact with the T4 temperature sensor |
|
E5 |
Contact with the T5 temperature sensor does not work |
|
E6 |
Water level exceeded in the pan tray |
|
E7 |
Contact with the T6 temperature sensor does not work |
|
E8 |
Invalid outdoor unit address |
|
Р1 |
High pressure protection |
|
P2 |
Low pressure protection |
|
P3 |
Compressor overcurrent protection |
|
R4 |
High discharge temperature protection |
|
Р5 |
Condensation temperature exceeded |
Error codes of external units for all semi-industrial models
|
Outdoor unit |
|
|
|
|
|
Three-phase models 36, 48, 60 kbtu, universal outdoor unit |
|
|||
|
Type |
Content |
LED1 |
LED2 |
LED3 |
|
OK |
Work |
Glows |
Off |
Off |
|
Mistake |
Incorrect phase rotation |
Blinks |
Off |
Off |
|
Mistake |
No one or two phases, phase imbalance A and B |
Blinks |
Off |
Off |
|
Mistake |
No phase C, imbalance in phase C |
Off |
Off |
Off |
|
Mistake |
Low pressure protection |
Blinks |
Blinks |
Off |
|
Mistake |
Over current |
Off |
Off |
Blinks |
|
Mistake |
Outdoor unit tube thermistor (T3) |
Off |
Blinks |
Blinks |
|
Mistake |
Outdoor unit thermistor by air (T4) |
Off |
Blinks |
Off |
|
OK |
Expectation |
Blinking (slow) |
Blinking (slow) |
Blinking (slow) |
MCC & MUC Series Indoor Error Codes
|
Mcc series indoor error codes (muc) |
||
|
Are displayed |
||
|
Code |
Type of error |
Actions |
|
E2 |
No contact / defective thermistor through air |
Check contact / replace thermistor by air |
|
E3 |
No contact / defective evaporator thermistor |
Check contact / replace evaporator thermistor |
|
E4 * |
No contact / defective capacitor thermistor |
Check contact / replace capacitor thermistor |
|
E5 *** |
No contact / defective condensate level sensor in the pan |
Check contact / replace sensor |
|
E6 ** |
Error / malfunction of the outdoor unit |
Look for errors on the outdoor unit board |
|
E7 |
Eeprom error of indoor unit |
Replace / reprogram eeprom indoor unit |
|
Е8 *** |
Condensate pan overflow |
Check the drainage system and pump |
|
* - only single-phase models! |
||
|
** - only three-phase models |
||
|
*** - mcc |
||
MUA & MCA Series Indoor Error Codes
|
Self-diagnosis |
|
|
|
|
|
Indoor unit |
|
|
|
|
|
No. |
A type |
Content |
Indication |
Note |
|
1 |
Protection |
Current overload, 4 times in 1 hour |
LED blinks operation+timer+defrosting |
The air conditioner does not work, resetting the error by turning off the power |
|
2 |
Protection |
Outdoor unit protection |
All leds blink |
Automatically reset to correct the error, except for the thermistor of the tube outdoor unit |
|
3 |
Error |
Indoor unit thermistor |
Flashing timer |
|
|
4 |
Error |
Thermistor tube indoor unit |
Operation flashes |
|
|
5 |
Error |
Outdoor unit tube thermistor |
Flashing defrosting |
|
|
6 |
Error |
Thermal protection |
Operation + timer flashing |
|
EACM Series Mobile Air Conditioner Error Codes
|
M-series mobile air conditioner error codes |
||
|
Are displayed |
||
|
Code |
Type of error |
Actions |
|
Р1 |
Level 1 overflow (upper pan) |
Drain condensate through the top plug |
|
P2 |
Level 2 overflow (lower pan) |
Drain condensate through the bottom plug |
|
E1 |
No contact / defective thermistor t1 |
Check contact / replace thermistor t1 |
|
E2 |
No contact / defective thermistor t2 |
Check contact / replace t2 thermistor |
|
E3 |
No contact / faulty thermistor t3 |
Check contact / replace t3 thermistor |
Midea MSMAAU-09HRDN1